Technical
Sample collection
The sample is cervical fluid collected from the endocervix with a dacron swab provided in the test package. After collection, the swab should be immediately transferred to the Specimen Extraction Solution and extracted by shaking the swab in the tube for 10 seconds. It is recommened to test the sample immediately, but if necessary the sample can also be stored for up to 4 hours before testing.
Storage of the test
The kit can be stored at +2-8 °C. Please note that the components need to reach room temperature before testing. The tests can be stored for 2 months also at room temperature, provided that the expiry date is not exceeded.
| Storage of the Kit | 2-8 °C | 18-30°C |
| Shelf life | until expiry date | 2 months |
Results in 5 minutes
Dip the dipstick in the sample solution and keep it there until the liquid front reaches the result area. Remove the dipstick from the sample and let it develop for 5 minutes in horizontal position.